Subscribe to get 20% off your first order. Click here

AMD P2 (N95 Standard) NANO-TECH Particulate Respirator, Four-layers (Box of 50)

On Sale
Zoom the image with the mouse
In stock
FREE SHIPPING IN AUSTRALIAYour order will be dispatched within 1-2 business days.Here are 7 reasons you’ll love these P2 face...
$149.00 $134.00
$134.00
AMD P2 (N95 Standard) NANO-TECH Particulate Respirator, Four-layers (Box of 50)

Product Reviews

See more reviews

Product Description

FREE SHIPPING IN AUSTRALIA

Your order will be dispatched within 1-2 business days.

Here are 7 reasons you’ll love these P2 face masks:

First P2/FFP2 certified respirator masks manufactured in Australia

Nano-filter filters out 99.66% of airborne particles like virus' as tested by VICLAB (BSI) 17.7.20 (compared to approximately 60% for many imported masks)

Authorized by FDA through EUA for medical use

Can be worn comfortably for up to 24 hours continuously

Australia & NZ standard AS/NZS 1716:2012

4 protective layers to protect you from airborne virus'

Cutting-edge nanotechnology, to make them light and breathable

Bacterial Filtration Efficiency (BFE)  ≥98% AS 4381 Level 3

Australia & NZ - P2 - AS/NZS 1716:2012;

Equivalent Product type Jurisdiction Relevant Standard Class:

Europe - FFP2 - EN 149-2001 FFP2

USA - N95 - NIOSH-42CFR84 N95 

China - KN95 - GB 2626:2019 KN95

 

PRODUCT INFO

Certifications & Reports

P2 / FFP2 NANO-TECH Particulate Respirator features advanced filtering and design details that allow them to be worn comfortably for extended periods of time while maintaining their class-leading functionality over standard melt blown filter respirators.

Cutting-edge nanofibre filters are incorporated into a face-contouring design that create an effective barrier against potentially harmful airborne particles and aerosols such as dust, virus, and bacteria. Nanofibre technology ensures excellent breathability and lightness even with the assurance of four protective layers.

Technology: Nano-filters, comprised of nano-fibres, deliver higher filtration efficiency than standard melt blown filters and are lighter and more breathable. They also maintain their functionality after exposure to moisture while typical filters lose their electrostatic properties once exposed to water. AMD’s nano-filters are water resistant and protective against airborne particles, aerosols, and liquid.

Fit: Innovative three panel design fits naturally around the nose and mouth creating a better seal and aesthetic. Elastic ear loops hold the respirator securely in place. A soft inner layer and moldable padded nose bridge wire provide extra comfort.

Comfort: Nano-filter respirators are lighter than standard respirators and allow enhanced breathability which allow them to be worn for hours. The three panel design unfolds to shape naturally around the face maximising ventilation around the nose and mouth while still maintaining an effective seal to the environment. Nano-filter respirators are potentially viable options for populations with breathing restrictions such as the elderly and those with heart and lung conditions.

Packaging: Each nano-filter respirator is individually packaged for hygiene and designed to fold flat to facilitate portability and storage. Individual wrapping makes it convenient to carry and distribute without contamination. 50/Box.

DIRECTIONS

Before putting on the respirator, wash hands for at least 20 seconds with soap and water or rub hands together thoroughly with alcohol-based hand sanitiser.

Take care not to touch the inside layer of the respirator that will be in contact with the nose and mouth when unpacking and while donning.

Check for defects in the face respirator such as tears or broken loops.

Position the label side of the respirator outward and orient the respirator so that the foam nose bridge strip is at the top.

Unfold the respirator while holding onto the edges (again being careful not to touch the area that will be in contact with the nose and mouth). Position the unfolded respirator over the nose and mouth and place one ear loop over each ear.

Mould the nose bridge wire to the bridge of the nose and while pinching the nose bridge in place stretch the bottom of the respirator to over the chin. Press along the edges of the respirator to maximise the seal.

Avoid touching the respirator while using it; if touched, clean hands with alcohol-based hand sanitiser or soap and water. 

Replace respirator if it becomes obviously contaminated; never reuse single-use respirators.

Removing the respirator

Wash hands with soap and water or alcohol-based hand sanitiser before removing the respirator. Remove the respirator by unhooking the ear loops, taking care not to touch the front of the respirator which might have become contaminated. Discard immediately in a closed bin and clean hands with alcohol-based hand sanitiser or soap and water.

SPECIFICATIONS

Brand AMD

Number per Box 50

Packaging Bulk Case

Features • Australian Made

• Cutting-edge nanofibre filters

• Four-layers with elastic ear loops

• Innovative three panel design improves fit and aesthetic and minimises gaps

• High breathability

• Soft, lightweight, comfortable & odourless

• Individually packed

• Latex free

Filter Included Yes

Face seal/ Nose foam Nose foam

Fluid Resistant (ASTM F1862) No

Flame Resistance (ASTM D2859-96) No

Flammability Rating Class 1

Product Colour White

Product Type Dust and other Particles

Respirator Style Flat Fold

Size Standard

Australia and New Zealand Compliance Standards P2

Standards/Approvals AS/NZS 1716:2012

 

Certification/Class P2

Filter performance ≥ 99.6%

Test agent NaCl

Flow rate 95 L/min

Total inward leakage (TIL) ≤ 8% leakage

Inhalation resistance ≤ 70 Pa (at 30L/min)≤ 240 Pa (at 95L/min)

Flow rate Varied – see above

Exhalation resistance ≤ 120 Pa

Flow rate 85L/min

Exhalation valve leakage requirement Leak rate ≤ 30mL/min

Force applied -250 Pa

CO2 clearance requirement ≤ 1%

PACKAGING DETAILS

WEIGHT 0.4 kg

DIMENSIONS 20 × 25 × 12 cm

WARNING

Selection of the most appropriate Respiratory Protective Equipment (RPE) will depend on the particular situation and should be made only by a competent person knowledgeable of the actual working conditions and the limitations of the RPE. Details regarding performance and limitations are specified on the respirator packaging and user instructions. Before using any respirator, the wearer must read and understand the user instructions for the product. Use in accordance with AS/NZS 1716:2012 Standard. Misuse can result in sickness or death. For more information, consult a supervisor or contact an Occupational Hygienist and Safety professional.

View Other Aussie Pharma Direct Products

Become a member today and get notified
about our latest products and special offers.

We use cookies to improve your experience on our website. Read about how we use cookies in our Privacy Policy. By browsing this website, you agree to our use of cookies.
You have successfully subscribed!
This email has been registered